Archives
- 2018-07
- 2019-06
- 2019-07
- 2019-08
- 2019-09
- 2019-10
- 2019-11
- 2019-12
- 2020-01
- 2020-02
- 2020-03
- 2020-04
- 2020-05
- 2020-06
- 2020-07
- 2020-08
- 2020-09
- 2020-10
- 2020-11
- 2020-12
- 2021-01
- 2021-02
- 2021-03
- 2021-04
- 2021-05
- 2021-06
- 2021-07
- 2021-08
- 2021-09
- 2021-10
- 2021-11
- 2021-12
- 2022-01
- 2022-02
- 2022-03
- 2022-04
- 2022-05
- 2022-06
- 2022-07
- 2022-08
- 2022-09
- 2022-10
- 2022-11
- 2022-12
- 2023-01
- 2023-02
- 2023-03
- 2023-04
- 2023-05
- 2023-06
- 2023-08
- 2023-09
- 2023-10
- 2023-11
- 2023-12
- 2024-01
- 2024-02
- 2024-03
- 2024-04
- 2024-05
- 2024-06
- 2024-07
- 2024-08
- 2024-09
- 2024-10
- 2024-11
- 2024-12
- 2025-01
-
Significance Our understanding of
2019-07-02
Significance Our understanding of the ubiquitin biology has been rapidly expanding. The role of the ubiquitin system in the pathogenesis of numerous disease states has increased the interest in finding new strategies to pharmacologically interfere with the enzymes responsible of the ubiquitination process.
-
Introduction Arrhythmogenic right
2019-07-01
Introduction Arrhythmogenic right ventricular cardiomyopathy (ARVC), previously called arrhythmogenic right ventricular dysplasia (ARVD), is an inherited disease characterized by right ventricular degeneration and ventricular arrhythmias. ARVC is one of the important causes of sudden cardiac deaths in young people, and especially in young athletes [1].
-
transparency has declined rather than
2019-06-29
However, transparency has declined rather than improved. A recent analysis in the ranked PEPFAR as very poor—50th of 67 aid agencies worldwide. The report noted that, “PEPFAR does not disclose information on contracts to prime partners and sub-partners in a machine-readable and open format consistent with the US Open Data Policy.”
-
The IntellaTip Mifi catheter
2019-06-28
The IntellaTip Mifi catheter has been shown to delineate local electograms better in the isthmus than the conventional bipolar electrode during atrial flutter ablation. The signal amplitude in the mini-electrodes has been noted to be higher than that of the conventional bipolar catheter.
-
Perioperative risk assessment of thromboembolism
2019-06-27
Perioperative risk assessment of thromboembolism The current thromboembolic risk stratification is largely based on indirect evidence from studies outside of the perioperative setting involving patients with a mechanical Cocktail valve, chronic atrial fibrillation or venous thromboembolism who either did not receive anticoagulation
-
Hello world!
2018-07-29
14376 records 959/959 page Previous First page 上5页 956957958959